建筑(zhu)物內使(shi)(shi)用(yong)(yong)的排(pai)(pai)水(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)(beng)有潛水(shui)(shui)(shui)排(pai)(pai)污(wu)泵(beng)(beng)(beng)(beng)(beng)、液(ye)下排(pai)(pai)水(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)(beng)、立式污(wu)水(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)(beng)和臥式污(wu)水(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)(beng)等。由于建筑(zhu)物內一般場地較小,排(pai)(pai)水(shui)(shui)(shui)量不(bu)大,排(pai)(pai)水(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)(beng)可優先采用(yong)(yong)潛水(shui)(shui)(shui)排(pai)(pai)污(wu)泵(beng)(beng)(beng)(beng)(beng)和液(ye)下排(pai)(pai)水(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)(beng),其中(zhong)液(ye)下排(pai)(pai)污(wu)泵(beng)(beng)(beng)(beng)(beng)一般在重要場所使(shi)(shi)用(yong)(yong);立式污(wu)水(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)(beng)和臥式污(wu)水(shui)(shui)(shui)泵(beng)(beng)(beng)(beng)(beng)要求設置隔震基礎、自(zi)灌(guan)式吸(xi)水(shui)(shui)(shui)、并(bing)占用(yong)(yong)一定(ding)的場地,故在建筑(zhu)中(zhong)較少使(shi)(shi)用(yong)(yong)。
1、當有(you)排(pai)(pai)水(shui)量(liang)調節時(shi)(shi),可按(an)生活排(pai)(pai)水(shui)大小(xiao)(xiao)時(shi)(shi)流(liu)量(liang)選定(ding)。消(xiao)防(fang)電(dian)梯集水(shui)池內排(pai)(pai)水(shui)泵(beng)(beng)流(liu)量(liang)不(bu)小(xiao)(xiao)于(yu)10L/s。 排(pai)(pai)水(shui)泵(beng)(beng)的(de)(de)揚程按(an)提(ti)升高度、管道損失計算(suan)確(que)定(ding)后(hou),再附(fu)加(jia)一定(ding)的(de)(de)自(zi)由(you)水(shui)頭(tou)。自(zi)由(you)水(shui)頭(tou)宜(yi)采(cai)用0.02~0.03MPa。排(pai)(pai)水(shui)泵(beng)(beng)吸(xi)水(shui)管和出水(shui)管流(liu)速不(bu)應小(xiao)(xiao)于(yu)0.7m/s,并(bing)不(bu)宜(yi)大于(yu)2.0m/s。 公共建筑內應以每個生活排(pai)(pai)水(shui)集水(shui)池為單元設(she)(she)置(zhi)一臺(tai)備用泵(beng)(beng),平時(shi)(shi)宜(yi)交互運行。地下室(shi)、設(she)(she)備機(ji)房、車(che)庫沖洗地面的(de)(de)排(pai)(pai)水(shui),如有(you)兩(liang)臺(tai)及兩(liang)臺(tai)以上(shang)排(pai)(pai)水(shui)泵(beng)(beng)時(shi)(shi)可不(bu)設(she)(she)備用泵(beng)(beng)。
2、當集水池(chi)無法(fa)設事故排水管(guan)時,水泵應有不間(jian)斷的(de)動力供(gong)應;
3、當能關閉排(pai)水(shui)(shui)進水(shui)(shui)管時,可不設(she)(she)不間斷動力(li)供應(ying)(ying),但應(ying)(ying)設(she)(she)置報警裝(zhuang)置。
4、當提升帶有較大雜質的污、廢水(shui)時,不同集水(shui)池內(nei)的潛水(shui)排污泵(beng)出水(shui)管(guan)不應合并排出。
5、當提升一(yi)般廢水(shui)(shui)時,可按實(shi)際情況考慮(lv)不(bu)同集水(shui)(shui)池的(de)潛水(shui)(shui)排污泵(beng)出(chu)水(shui)(shui)管合并(bing)排出(chu)。兩臺(tai)(tai)或(huo)兩臺(tai)(tai)以上的(de)水(shui)(shui)泵(beng)共(gong)用一(yi)條(tiao)出(chu)水(shui)(shui)管時,應在每臺(tai)(tai)水(shui)(shui)泵(beng)出(chu)水(shui)(shui)管上裝設閥(fa)門和(he)止回(hui)閥(fa)。單臺(tai)(tai)水(shui)(shui)泵(beng)排水(shui)(shui)有可能產生倒灌時,應設止回(hui)閥(fa)。不(bu)允許(xu)壓力排水(shui)(shui)關與建(jian)筑內重力排水(shui)(shui)管合并(bing)排出(chu)。
6、當潛水排污(wu)(wu)泵(beng)提(ti)升含有大(da)塊雜物(wu)時(shi),潛水排污(wu)(wu)泵(beng)宜(yi)帶(dai)有粉(fen)碎裝置(zhi);當提(ti)升含較(jiao)多纖(xian)維物(wu)污(wu)(wu)水時(shi),宜(yi)采用大(da)通(tong)道潛水排污(wu)(wu)泵(beng)。
7、當電(dian)機功率大于(yu)等于(yu)7.5kW或(huo)出水口管徑大于(yu)等于(yu)DN100時(shi),可采用水泵固定自耦裝置;
8、當(dang)潛水(shui)(shui)排(pai)污(wu)(wu)電泵電機功率(lv)小于7.5kW或出(chu)水(shui)(shui)口管徑小于DN100時,可(ke)設軟(ruan)管移動(dong)式安裝。污(wu)(wu)水(shui)(shui)集水(shui)(shui)池采用潛水(shui)(shui)排(pai)污(wu)(wu)泵排(pai)水(shui)(shui)時,應設水(shui)(shui)泵固(gu)定自(zi)耦裝置,方便水(shui)(shui)泵檢(jian)修。排(pai)水(shui)(shui)泵應能(neng)自(zi)動(dong)啟停(ting)和(he)現場手動(dong)啟停(ting)。多(duo)臺水(shui)(shui)泵可(ke)并聯交(jiao)替運(yun)行,也可(ke)分段投入運(yun)行。
注意事項:
(1)當濕(shi)度傳(chuan)感器或(huo)溫度傳(chuan)感器發(fa)出報警時,或(huo)泵體(ti)運轉時振動(dong)、噪聲(sheng)出現異常時;或(huo)輸(shu)出水(shui)(shui)量水(shui)(shui)壓下降(jiang)、電能消耗顯著上(shang)升(sheng)時,應當立(li)即(ji)對(dui)潛水(shui)(shui)排污(wu)泵停機進行(xing)檢修(xiu)。
(2)有些密封不(bu)好的(de)(de)(de)(de)潛水(shui)泵長期浸(jin)泡在水(shui)中時(shi)(shi),即使不(bu)使用(yong)(yong)(yong),絕(jue)(jue)緣值也會逐漸(jian)下降(jiang),終無法投用(yong)(yong)(yong),甚到(dao)在比連續運轉的(de)(de)(de)(de)潛水(shui)排污泵在水(shui)中的(de)(de)(de)(de)工作時(shi)(shi)間(jian)還短的(de)(de)(de)(de)時(shi)(shi)間(jian)內發生絕(jue)(jue)緣消(xiao)失(shi)現象。因此(ci)潛水(shui)泵在吸(xi)水(shui)池(chi)內備(bei)用(yong)(yong)(yong)有時(shi)(shi)起(qi)不(bu)到(dao)備(bei)用(yong)(yong)(yong)的(de)(de)(de)(de)作用(yong)(yong)(yong),如果條件(jian)許可,可以在池(chi)外干式(shi)備(bei)用(yong)(yong)(yong),等運行中的(de)(de)(de)(de)某臺潛水(shui)泵出現故障時(shi)(shi),立即停機(ji)提(ti)升上來(lai)后,將備(bei)用(yong)(yong)(yong)泵再放下去。
(3)潛(qian)水(shui)泵不(bu)能過于頻繁開(kai)(kai)、停(ting),否則(ze)將(jiang)影響潛(qian)水(shui)泵的(de)使用壽(shou)命。潛(qian)水(shui)泵停(ting)止時,管路內的(de)水(shui)產生回流,此時立(li)即再啟動(dong)則(ze)引(yin)起電泵啟動(dong)時的(de)負(fu)載(zai)(zai)過重,并(bing)承受(shou)不(bu)需(xu)要的(de)沖(chong)擊(ji)載(zai)(zai)荷(he);另外,潛(qian)水(shui)泵過于頻繁開(kai)(kai)、停(ting)將(jiang)損壞承受(shou)沖(chong)擊(ji)能力較差(cha)的(de)零部件,并(bing)帶來整個(ge)電泵的(de)損壞。
(4)停(ting)機后(hou),在(zai)電機停(ting)止(zhi)運轉前,不能重新啟動。
(5)檢查(cha)電(dian)泵時(shi)須切斷(duan)電(dian)源。
(6)潛(qian)水(shui)泵工作時(shi),不要在附近洗滌物品、游(you)泳或(huo)放牲(sheng)畜(chu)下水(shui),以免電泵漏電時(shi)發生(sheng)觸(chu)電事故